Determination of organic hydrocarbons VDI 3874/CEN 15439
Sampling line for PCB and PAH according to VDI 3874
PCB = Polychlorinated Biphenyls, PAH = Polycyclic Aromatic Hydrocarbons.
Sampling according to VDI 3874.
System developed from HLUG (Hessian Agency for the Environment and Geology):
- cooled condensate trap
- small double XAD adsorption trap.
Information
You need further information or an offer?
Measurement of TAR according to CEN/TS draft 15439
Sampling line for the TAR determination
Construction according to CEN/TS 15439:
- sampling according to EN 13284-1, heated thimble filter,
- absorption through 6 bubbler in isolated inox box, with two separate sections,
- last trap is one XAD-cartridge.
Size of the inox box (length x wide x high): 430 x 245 x 320 mm.
(Please specify the desired length of the probe in the request)