Print

Tar sampling according to CEN/TS 15439

Tar sampling according to CEN/TS 15439

Measurement of TAR according to CEN/TS draft 15439


Picture left  enlarged (sampling module)


Sampling line for the TAR determination

 

Construction according to CEN/TS 15439:

  • Modul 1: Heated sampling probe according to EN 13284-1,
  • Modul 2: Heated valve and thimble filter,
  • Modul 3: Absorption through 6 bubbler in two differentially tempered sections,
  • Modul 4: Volume flow measurement: pump and gas meter.

 

Information

 
(Please specify the desired length of the probe in the request)

Display per page
Sort by
Product no.: TE-H-FI

Modul 2: Filter and valve inside the heater for the determination of TAR according to CEN/TS draft 15439

2,943.00 *

Product has a longer production time
can be shipped within 25-30 days

Product no.: TE-H

Modul 2: Big heater for TAR sampling line with flange in front of the heater casing to fix the heater at the suction tube.

1,224.00 *

Product has a longer production time
can be shipped within 25-30 days

Product no.: TE-CO-CEN

Modul 3: cooling System according to the CEN Standard (Draft CEN/BT/TF 143), including all glass parts.

4,311.00 *

Product has a longer production time
can be shipped within 25-30 days

Product no.: 44.01

Stable clamps to fix the connection with spherical joints from pan and ball KS 19 (glass and Titanium).

14.00 *

Manufacturing time
can be shipped within 3-5 days

With heater cartridge (~ 500 W / m), outer-diameter: Ø 25 mm,
Entrance: Internal thread G ½, Exit: External thread G ½.

2,921.00 *
Product data sheet

Manufacturing time
can be shipped within 14-21 days

Product no.: 26.03

Complete sampling rack with dry running rotary vane vacuum pump, gas meter and flow meter.

4,436.00 *

Manufacturing time
can be shipped within 28 days

*
Prices without VAT or delivery